Hirose, Orie’s team published research in Modern Rheumatology in 2015 | 6055-19-2

Modern Rheumatology published new progress about Blood analysis. 6055-19-2 belongs to class chlorides-buliding-blocks, and the molecular formula is C7H17Cl2N2O3P, Formula: C7H17Cl2N2O3P.

Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku published the artcile< Comparison of a novel chemiluminescence enzyme immunoassay (CLEIA) with enzyme-linked immunosorbent assay (ELISA) for the determination of MPO-ANCA in patients with ANCA-associated vasculitis>, Formula: C7H17Cl2N2O3P, the main research area is chemiluminescence enzyme immunoassay ELISA MPO ANCA human AAV; ANCA-associated vasculitis; BVAS; CLEIA; ELISA; MPO-ANCA.

Background. Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serol. hallmark of ANCA-associated vasculitis (AAV). We evaluated the anal. and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) vs. ELISA for the detection of MPO-ANCA. Methods. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. Results. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p < 0.0001). At the cutoff value of 3.5 U/mL, the CLEIA yielded pos. test results for MPO-ANCA in 73 of the 242 sera (30.2%), while at the cutoff value of 20 U/mL, ELISA yielded pos. test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-pos. test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-pos. result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, resp., while those of the ELISA were 94.3% and 99.2%, resp. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, resp., while those of the ELISA were 94.3% and 73.6%, resp. Conclusion. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA. Modern Rheumatology published new progress about Blood analysis. 6055-19-2 belongs to class chlorides-buliding-blocks, and the molecular formula is C7H17Cl2N2O3P, Formula: C7H17Cl2N2O3P.

Referemce:
Chloride – Wikipedia,
Chlorides – an overview | ScienceDirect Topics