Khan, Mohammad Rizwan et al. published their research in RSC Advances in 2014 |CAS: 4569-86-2

The Article related to environmental sample methylene blue spe uplc tandem mass spectrometry, Water: Analysis and other aspects.Safety of 3-Amino-7-(diethylamino)-5-phenylphenazin-5-ium chloride

Khan, Mohammad Rizwan; Khan, Moonis Ali; Alothman, Zeid Abdullah; Alsohaimi, Ibrahim Hotan; Naushad, Mu; Al-Shaalan, Nora H. published an article in 2014, the title of the article was Quantitative determination of methylene blue in environmental samples by solid-phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry: a green approach.Safety of 3-Amino-7-(diethylamino)-5-phenylphenazin-5-ium chloride And the article contains the following content:

Industrial effluents with dyes may contain appreciable concentrations of materials with high COD and suspended solids, posing adverse effects to both humans and aquatic life; therefore, these effluents require quant. monitoring. In the present study, an anal. method based on solid-phase extraction (SPE) and ultra-performance liquid chromatog.-tandem mass spectrometry (UPLC-MS/MS) has been optimized for the quant. anal. of methylene blue (MB) in environmental samples. For the extraction of MB, a variety of solvents, including formic acid, were investigated to obtain optimum recovery. MB extraction using the SPE method was best achieved using methanol with 1 M formic acid. Chromatog. separation of MB and methylene violet 3RAX (MV 3RAX, internal standard) was accomplished on an Acquity BEH C18 column using water (64.99%) with formic acid (0.01%) and acetonitrile (35%) in isocratic elution mode. Chromatog. separation for both MB and MV 3RAX was achieved in <2 min with good resolution and superior peak symmetry. MB and MV 3RAX were quantified with electrospray ionization coupled with MS/MS in the multiple reaction monitoring mode. Good quality parameters were achieved for instance linearity (r2 > 0.999), run-to-run and day-to-day precisions with relative standard deviations of <4%, sensitivity with a low limit of detection (LOD) of 0.1 ng mL-1 and limit of quantification (LOQ) of 0.4 ng mL-1 were obtained. Industrial wastewater samples (paper, textile, laundry and printing press) were analyzed, and an MB level was found in between 0.36 and 1.08 μg mL-1 with excellent recovery rates (95-99%) depending on samples. The experimental process involved the reaction of 3-Amino-7-(diethylamino)-5-phenylphenazin-5-ium chloride(cas: 4569-86-2).Safety of 3-Amino-7-(diethylamino)-5-phenylphenazin-5-ium chloride

The Article related to environmental sample methylene blue spe uplc tandem mass spectrometry, Water: Analysis and other aspects.Safety of 3-Amino-7-(diethylamino)-5-phenylphenazin-5-ium chloride

Referemce:
Chloride – Wikipedia,
Chlorides – an overview | ScienceDirect Topics